Welgard
All Inspections

Marlene Hutchins

44 Old Orchard Lane, Roanoke, VA

WRP-2026-U82QP

Edit
View
Not Approved

The well system has significant issues that must be resolved before the property can qualify for coverage. Required repairs must be completed and the system re-inspected.

0System score / 100

Evaluation notes:

  • Contamination risk detected — immediate disqualifier.
Member & Property
OwnerMarlene Hutchins
Emailm.hutchins@verizon.net
Phone555-811-6600
Property Address44 Old Orchard Lane, Roanoke, VA, 24012
Inspection Source
InspectorDiana Reyes
CompanySummit Well & Pump
DateMar 28, 2026
ActivityIneligible
Well System
Well Typedrilled
Well Depth175 ft
Pump Typesubmersible
Pump Age8 yrs
Pressure Tank Age8 yrs
Conditions
Casinggood
Well Capfair
Wiringgood
Safety IssuesYes
Contamination RiskNo
Visible LeaksYes
System OperationalYes
Pressure OKYes
Flow OKYes
Site Clearance OKYes
Notes & Findings

Inspector Notes

Mechanical systems in reasonable condition. Lab water sample returned elevated coliform and nitrate levels exceeding EPA limits. Contamination source believed to be nearby agricultural runoff.

Internal Notes

Despite mechanical score of 66 (yellow), contamination finding triggers automatic not-approved override per policy section 4.2.

Required Repairs

Shock chlorination treatment immediately. Reseal wellhead cap. Quarterly water testing for 12 months minimum.

Member-Facing Summary

While your well equipment is in reasonable mechanical condition, water quality testing revealed contamination that exceeds safe limits.